1.
Arch Orthop Trauma Surg ; 140(2): 209-218, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31748883

RESUMO

BACKGROUND: The goal of this study was to share our experience with two different inlay metallic implants in the treatment of knee cartilage defects and to analyze their effects on functional scores. METHODS: This retrospective study included 118 patients operated on for focal full-thickness knee cartilage lesions, who were treated with a focal metallic inlay resurfacing prosthesis. A cobalt-chromium (Co-Cr) resurfacing implant was applied to 73 patients with a knee chondral lesion, and a biosynthetic implant was applied to 45. All patients were evaluated preoperatively and postoperatively using the KOOS, VAS, and Tegner activity scores. RESULTS: The group with the Co-Cr-resurfacing implant showed a significantly greater improvement (p < 0.001) in the Tegner and VAS scores at the 2-year follow-up examination. The KOOS scores were similar in both groups. Median patient age was similar in both groups. All patients had a follow-up of at least 2 years. The preoperative and postoperative scores were compared and significant improvements (p < 0.001) were observed. The biosynthetic implant had a higher revision rate. In the univariate analysis, age and type of implant were significantly associated with revision surgery. In the multivariate Cox-regression analysis model, the type of implant was significantly associated with revision surgery. CONCLUSION: All the patients operated with the above-mentioned implants showed significant improvements in pain and activity scores. Despite the overall good clinical results, 17% of patients with a biosynthetic implant and > 6% of patients with Co-Cr-resurfacing implant required revision surgery. Age and implant type were the main risk factors associated with revision.


Assuntos
Doenças das Cartilagens/cirurgia , Cartilagem Articular/cirurgia , Articulação do Joelho/cirurgia , Prótese do Joelho , Ligas de Cromo/uso terapêutico , Humanos , Prótese do Joelho/efeitos adversos , Prótese do Joelho/estatística & dados numéricos , Estudos Retrospectivos , Resultado do Tratamento
2.
Surg Technol Int ; 33: 332-336, 2018 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-29985516

RESUMO

BACKGROUND: Lower extremity total joint arthroplasty (TJA) is one of the most successful orthopaedic procedures. However, it is estimated that as many as 10% to 20% of TJAs could fail due to various well-known causes. Furthermore, metal allergy-related complications have recently gained attention as one of the potential causes of failure when the common reasons have been excluded. Reported symptoms from metal allergy can include chronic eczema, joint effusions, joint pain, and limited range of motion. Few studies have explored the outcomes of patients undergoing revisions due to allergic complications. The aim of our study is to quantitatively evaluate the outcomes of revision joint arthroplasty due to metal allergy and hypersensitivity.


Assuntos
Artroplastia de Quadril/efeitos adversos , Artroplastia do Joelho/efeitos adversos , Ligas de Cromo/efeitos adversos , Dermatite de Contato/cirurgia , Reoperação/estatística & dados numéricos , Adulto , Idoso , Idoso de 80 Anos ou mais , Ligas de Cromo/uso terapêutico , Dermatite de Contato/etiologia , Feminino , Prótese de Quadril/efeitos adversos , Humanos , Prótese do Joelho/efeitos adversos , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Resultado do Tratamento
3.
J Prosthet Dent ; 120(3): 409-414, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29724558

RESUMO

STATEMENT OF PROBLEM: Limited information is available on the precision of new metal processing technologies. PURPOSE: The purpose of this in vitro study was to evaluate the marginal and internal fit of pre-sintered cobalt-chromium (Co-Cr) and zirconia 3-unit fixed dental prostheses using x-ray microcomputed tomography. MATERIAL AND METHODS: Three-unit fixed dental prostheses were prepared on metal dies (N=12) using a typodont model from the maxillary first premolar to the first molar. A standardized preparation with a 1.2-mm chamfer (360 degrees) and a 2-mm occlusal reduction was prepared on abutment teeth. The dies were scanned and divided into 2 groups to receive the fixed dental prostheses (n=6) made of pre-sintered Co-Cr and pre-sintered zirconia. Each framework was seated on its cast, and marginal and internal discrepancies were measured at 9 points, starting from the most distal point from the pontic for the maxillary first premolar and the first molar (points 1-4, mesial; point 5, occlusal; points 6-9, distal) of each abutment tooth using microcomputed tomography. The data were analyzed using the Levene test, t test, and ANOVA (α=.05). RESULTS: When overall mean discrepancy values were compared, no significant difference was observed between pre-sintered Co-Cr and pre-sintered zirconia (P=.085). Discrepancy values for points 1, 2, and 3 were significantly different for pre-sintered Co-Cr and pre-sintered zirconia, with the lowest mean values for point 1 and the highest for point 5. On the abutment tooth basis, for the maxillary first premolar and the first molar, a significant difference was found only in points 6 (P<.001) and 8 (P<.003) for both materials. When the discrepancies for the maxillary first premolar were considered for pre-sintered Co-Cr and pre-sintered zirconia, the mean values were significantly different only at points 1 (P<.001), 2 (P=.007), and 3 (P=.003) and were smaller for pre-sintered zirconia. For the tooth the first molar, a significant difference was observed at point 2 (P=.002) and point 3 (P=.008) for both materials, where the mean values were higher for pre-sintered Co-Cr than for pre-sintered zirconia. The pairwise comparison between points showed a significant difference between measurement points within each material (P<.05). The increase in values between points 1 and 5 was evident for both pre-sintered Co-Cr and pre-sintered zirconia materials. CONCLUSIONS: Three-unit fixed dental prostheses made of pre-sintered Co-Cr or zirconia showed similar marginal and internal discrepancy values, with the highest discrepancy values at the occlusal region in both the first premolar and first molar.


Assuntos
Adaptação Marginal Dentária , Prótese Dentária , Ligas de Cromo/uso terapêutico , Desenho Assistido por Computador , Planejamento de Prótese Dentária , Humanos , Radiografia Dentária , Microtomografia por Raio-X , Zircônio/uso terapêutico
4.
Int J Periodontics Restorative Dent ; 38(Suppl): s79­s85, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29253041

RESUMO

Although implant therapy in esthetically relevant areas is currently based on a prosthetically driven philosophy, anatomical and technical factors may impair ideal implant placement. In these scenarios, the clinician is frequently asked to solve the discrepancy between the implant emergence and the ideal coronal anatomy of the final restoration. This report describes how changes of the implant abutment-crown contour in specific locations may be intentionally promoted to determine improvements of the peri-implant soft tissues and overall esthetic integration. Cobalt-chromium alloys together with computer-aided design/computer-assisted manufacture technologies are critical factors in achieving this goal. Case reports for the mandibular anterior dentition demonstrated the ability to enhance biologic and esthetic results of malpositioned implants.


Assuntos
Ligas de Cromo/uso terapêutico , Desenho Assistido por Computador , Projeto do Implante Dentário-Pivô/métodos , Implantação Dentária Endóssea/métodos , Implantes Dentários , Idoso , Dente Suporte , Restauração Dentária Permanente/métodos , Estética Dentária , Feminino , Humanos , Masculino
5.
Av. odontoestomatol ; 33(4): 151-160, jul.-ago. 2017.
Artigo em Espanhol | IBECS | ID: ibc-165581

RESUMO

El objetivo del presente trabajo es realizar una revisión bibliográfica de los últimos diez años a cerca de la instrumentación rotatoria en endodoncia y de los diferentes tipos de limas que se pueden usar, buscando una comparativa de ventajas y desventajas e incluso posibles indicaciones para cada caso y tipo de lima o procedimiento. EL sistema de endodoncia rotatoria ha significado un avance extraordinario en el tratamiento de conductos tanto de dientes anteriores como posteriores. La instrumentación rotatoria permite utilizando un menor número de limas, darle una mayor conicidad que facilite la limpieza del conducto y su posterior obturación. Por ello se pretende explicar la técnica de instrumentación mecánica de los conductos radiculares, exponiendo su diseño, características de composición, forma de uso y las ventajas o inconvenientes respecto a otros sistemas (AU)


The objective of the present work is to perform a literature review of the last ten years about rotary instrumentation in endodontics and the different types of files that can be used, searching for a comparative of advantages and disadvantages and even possible indications for each case. File type or procedure. The rotational endodontic system has meant an extraordinary advance in the treatment of ducts of both anterior and posterior teeth. The rotary instrumentation allows using a smaller number of files, give a greater conicity that facilitates the cleaning of the duct and its subsequent obturation. The aim of this work is to explain the technique of mechanical instrumentation of the root canal, exposing its design, characteristics of composition, form of use and the advantages or disadvantages with respect to other systems (AU)


Assuntos
Humanos , Preparo de Canal Radicular/instrumentação , Instrumentos Odontológicos/classificação , Rotação , Ligas de Cromo/uso terapêutico , Endodontia/história
6.
World Neurosurg ; 103: 404-409, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28427980

RESUMO

BACKGROUND: The use of titanium alloy (Ti) rods is frequently associated with rod fracture after spinal fixation. To address this issue, cobalt chrome (CoCr) rods, which are advantageous because of their greater strength and resistance to fatigue relative to Ti rods, have been introduced. The purpose of the present study was to compare radiographic outcomes after the use of Ti versus CoCr rods in a matched cohort of patients undergoing posterior spinal fusion for treatment of spinal instability. METHODS: We retrospectively reviewed data from patients who had undergone spinal fusion involving more than 3 levels at a single institution between 2004 and 2015. Patients were matched for age, diagnosis, 3-column osteotomy, levels fused, and T score. Fifty patients with Ti rods were identified and appropriately matched to 50 consecutive patients with CoCr rods. RESULTS: The distributions of age at surgery, sex, diagnosis, 3-column osteotomy, levels fused, number of patients with previous surgical procedures, and T score did not significantly differ between the 2 groups. However, there were significant differences in length of follow-up (CoCr, 25.0 vs. Ti, 28.5 months; P < 0.001), fusion rate (CoCr, 45 [90%] vs. Ti, 33 [66%]; P = 0.004), occurrence of rod breakage (CoCr, 0 vs. T, 8 [16%]; P = 0.006), and junctional kyphosis (CoCr, 24 [46%] vs. Ti, 9 [18%]; P = 0.003). CONCLUSIONS: Our findings indicate that the use of CoCr rods is effective in ensuring stability of the posterior spinal construct and accomplishment of spinal fusion. Furthermore, our results indicate that junctional kyphosis may occur more frequently in CoCr systems than in Ti systems.


Assuntos
Ligas de Cromo/uso terapêutico , Cobalto/uso terapêutico , Cifose/etiologia , Fusão Vertebral/instrumentação , Titânio/uso terapêutico , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Fixadores Internos , Instabilidade Articular/diagnóstico por imagem , Instabilidade Articular/cirurgia , Cifose/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Doenças da Coluna Vertebral/diagnóstico por imagem , Doenças da Coluna Vertebral/cirurgia , Resultado do Tratamento , Adulto Jovem
7.
J Prosthet Dent ; 118(5): 672-677, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28385435

RESUMO

STATEMENT OF PROBLEM: The use of computer-aided design and computer-aided manufacturing (CAD-CAM) for metal-ceramic restorations has increased with advances in the technology. However, little is known about the marginal and internal adaptation of restorations fabricated using laser sintering (LS) and soft milling (SM). Moreover, the effects of repeated ceramic firings on the marginal and internal adaptation of metal-ceramic restorations fabricated with LS and SM is also unknown. PURPOSE: The purpose of this in vitro study was to investigate the effects of repeated ceramic firings on the marginal and internal adaptation of metal-ceramic copings fabricated using the lost wax (LW), LS, and SM techniques. MATERIAL AND METHODS: Ten LW, 10 LS, and 10 SM cobalt-chromium (Co-Cr) copings were fabricated for an artificial tooth (Frasaco GmbH). After the application of veneering ceramic (VITA VMK Master; VITA Zahnfabrik), the marginal and internal discrepancies of these copings were measured with a silicone indicator paste and a stereomicroscope at ×100 magnification after the first, second, and third clinical simulated ceramic firing cycles. Repeated measures 2-way ANOVA and the Fisher LSD post hoc test were used to evaluate differences in marginal and internal discrepancies (α=.05). RESULTS: Neither fabrication protocol nor repeated ceramic firings had any statistically significant effect on internal discrepancy values (P>.05). Marginal discrepancy values were also statistically unaffected by repeated ceramic firings (P>.05); however, the fabrication protocol had a significant effect on marginal discrepancy values (P<.001), with LW resulting in higher marginal discrepancy values than LS or SM (P<.05). Marginal discrepancy values did not vary between LS and SM (P>.05). CONCLUSIONS: All groups demonstrated clinically acceptable marginal adaptation after repeated ceramic firing cycles; however, the LS and SM groups demonstrated better marginal adaptation than that of LW group and may be appropriate clinical alternatives to LW.


Assuntos
Cerâmica/uso terapêutico , Desenho Assistido por Computador , Adaptação Marginal Dentária , Planejamento de Prótese Dentária/métodos , Restauração Dentária Permanente/métodos , Ligas de Cromo/uso terapêutico , Prótese Parcial Removível , Humanos , Técnicas In Vitro
8.
Biomed Res Int ; 2016: 1695906, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27433471

RESUMO

Tribocorrosion in taper junctions of retrieved anatomic shoulder arthroplasty implants was evaluated. A comparison of the tribocorrosion between cobalt-chromium and titanium alloy stems was conducted and the observations were correlated with the individual's clinical data. Adverse effects caused by metal debris and subsequent elevated serum metal ion levels are frequently reported in total hip arthroplasty. In total shoulder arthroplasty, to date only a small number of retrieval analyses are available and even fewer address the issue of tribocorrosion at the taper junctions. A total of 36 retrieved hemiarthroplasties and total shoulder arthroplasties were assessed using the modified Goldberg score. The prevalence of fretting and corrosion was confirmed in this cohort. Titanium stems seem to be more susceptible to damage caused by tribocorrosion than cobalt-chromium stems. Furthermore, stemless designs offered less tribocorrosion at the taper junction than stemmed designs. A weak correlation between time to revision and increased levels of tribocorrosion was seen. Whether or not tribocorrosion can lead to adverse clinical reactions and causes failure of shoulder arthroplasties remains to be examined.


Assuntos
Artroplastia/métodos , Ligas de Cromo/uso terapêutico , Ombro/cirurgia , Titânio/uso terapêutico , Idoso , Idoso de 80 Anos ou mais , Feminino , Hemiartroplastia/métodos , Quadril/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade
9.
J Prosthet Dent ; 116(3): 368-74, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27130177

RESUMO

STATEMENT OF PROBLEM: Marginal and axial discrepancies of metal ceramic restorations are key to their long-term success. Little information is available for metal ceramic restorations fabricated with soft metal milling and laser sintering technologies. PURPOSE: The purpose of this in vitro study was to compare the marginal, axial, and occlusal discrepancies in single-unit metal ceramic restorations fabricated with new production techniques with those in a single-unit restoration fabricated using a conventional technique. MATERIAL AND METHODS: After the artificial tooth was prepared, impressions were made, and 40 dies were obtained. Dies were randomly divided into 4 groups (n=10). Cobalt-chromium (Co-Cr) cast (C), hard metal milled (HM), laser sintered (LS), and soft metal milled (SM) copings were fabricated. Marginal, axial, and occlusal discrepancies of these copings were measured using the silicone replica technique before and after the application of veneering ceramic. Data were analyzed with repeated measurements 2-way ANOVAs and Bonferroni post hoc tests (α=.05). RESULTS: Significant differences were found in the increase of marginal discrepancy after the application of veneering ceramic in the LS group (P=.016). However, no significant differences in marginal discrepancy were found whether veneering ceramic was applied to copings before or after in the other groups (P>.05). With regard to marginal and occlusal discrepancies, significant differences were found among the production techniques (P<.001 and P<.05, respectively). No significant differences in axial discrepancies were found among the groups (P>.05). CONCLUSION: This in vitro study showed that metal ceramic restorations produced with HM and newly introduced SM techniques exhibited better marginal adaptations than those produced with the LS or C technique.


Assuntos
Planejamento de Prótese Dentária/métodos , Restauração Dentária Permanente/métodos , Ligas Metalo-Cerâmicas/uso terapêutico , Ligas de Cromo/uso terapêutico , Desenho Assistido por Computador , Adaptação Marginal Dentária/normas , Oclusão Dentária , Planejamento de Prótese Dentária/instrumentação , Planejamento de Prótese Dentária/normas , Restauração Dentária Permanente/instrumentação , Restauração Dentária Permanente/normas , Humanos , Técnicas In Vitro , Dente Artificial
10.
Spine (Phila Pa 1976) ; 41(7): E388-95, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27018904

RESUMO

STUDY DESIGN: In vitro cadaveric biomechanical study. OBJECTIVE: To assess effects of 4-rod reconstruction, rod material, and anterior column support on motion and surface rod strain in a pedicle subtraction osteotomy model. SUMMARY OF BACKGROUND DATA: Pedicle subtraction osteotomy (PSO) can correct significant sagittal deformity of the lumbar spine; however, revision rates are high. To reduce rod strain and the incidence of rod fracture, clinical use of multi-rod construction, cobalt chrome (CoCr) alloy rods, and interbody spacers adjacent to PSO has been proposed. Investigating both motion and rod strain is necessary to determine the biomechanical efficacy of these techniques. METHODS: Five specimens (T12-S1) underwent PSO at L3 with pedicle screw stabilization at L1-S1. Pedicle subtraction was adjusted to achieve a final lordosis of 70°. Flexion-extension (FE), lateral bending, and axial rotation were applied. Linear strain gauges measured surface rod strain during FE on primary and accessory rods at PSO level. Testing evaluated (1) accessory rods (4-Rod) added at PSO level versus primary rods (2-Rod); (2) Ti versus CoCr rods; and (3) lateral interbody spacers (S) inserted adjacent to PSO. One-way and three-way analysis of variance was performed (P ≤ 0.05). RESULTS: All constructs significantly reduced FE and lateral bending motion relative to intact (P < 0.001). The main effect of accessory rods in reducing FE motion was significant (P = 0.021). Accessory and CoCr rods reduced relative surface strain on the primary rod, irrespective of construct (P < 0.001). CoCr 4-Rod + S provided the greatest reduction in strain (76% decrease; P = 0.003). CONCLUSION: Accessory and CoCr rods provided greatest reduction in motion and rod strain at PSO level. Interbody devices minimally affected motion-induced strain and might act primarily to maintain disc height. Clinicians must assess whether surface strain and motion reduction minimize the incidence of rod fracture. LEVEL OF EVIDENCE: N/A.


Assuntos
Ligas de Cromo/uso terapêutico , Fixadores Internos , Vértebras Lombares/fisiologia , Vértebras Lombares/cirurgia , Osteotomia/instrumentação , Amplitude de Movimento Articular/fisiologia , Fusão Vertebral/instrumentação , Fenômenos Biomecânicos , Humanos , Modelos Biológicos
11.
Spine (Phila Pa 1976) ; 41(6): 502-7, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26966974

RESUMO

STUDY DESIGN: Retrospective case series of one institute database. OBJECTIVE: To investigate the differences in the metallic strength of rods used for implant failure in the dual growing rod technique and evaluate clinical outcomes. SUMMARY OF BACKGROUND DATA: The dual growing rod technique in which implanted rods extend with the growth of the spine is a useful treatment for early onset scoliosis. However, many complications, particularly those associated with rods, exist. Especially, the implant failure of growing rod focused on metallic strength is unknown. METHODS: Thirteen patients (42 lengthening surgeries) who underwent surgery by this technique at our hospital from 2007 were divided into a titanium rod plus titanium connector group (T group, n = 4, 26 lengthening surgeries) and cobalt-chromium rod plus titanium connection group (C group, n = 9, 16 lengthening surgeries). The incidence of implant failure and the site of fracture were retrospectively investigated. RESULTS: Implant failure occurred in three patients in the T group, because of rod fracture in two patients and connector fracture in one. In the C group, implant failure occurred in six patients, because of rod fracture in one patient and connector fracture in seven. Fracture occurred twice in two patients. The rod fracture rate decreased with the use of cobalt-chromium rods but the rate of connector fracture increased. We performed a stress distribution analysis using the finite element method to clarify the mechanisms underlying implant failure in both groups. Regardless of the rod type, the greater load was placed on the distal rod. However, differences in the metallic strength caused the rod to fracture when titanium rods were used and connectors (weak metallic strength) to fracture when cobalt-chromium rods were used. CONCLUSION: Rod fractures occurred more commonly with titanium rods and connector fractures with cobalt-chromium rods.


Assuntos
Ligas de Cromo/uso terapêutico , Procedimentos Ortopédicos/efeitos adversos , Procedimentos Ortopédicos/instrumentação , Falha de Prótese , Escoliose/cirurgia , Titânio/uso terapêutico , Alongamento Ósseo , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Procedimentos Ortopédicos/métodos , Procedimentos Ortopédicos/estatística & dados numéricos , Complicações Pós-Operatórias , Estudos Retrospectivos , Escoliose/diagnóstico por imagem , Escoliose/patologia
12.
Biomed Res Int ; 2015: 283038, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26583097

RESUMO

Metal transfer has been observed on retrieved THA femoral heads for both CoCr and ceramic bearing materials. In vitro wear testing has shown increased wear to polyethylene acetabular liners with the presence of metal transfer. This study sought to investigate the extent of metal transfer on the bearing surface of CoCr and ceramic femoral heads and identify prevalent morphologies. Three bearing couple cohorts: M-PE (n = 50), C-PE (n = 35), and C-C (n = 15), were derived from two previously matched collections (n = 50/group) of CoCr and ceramic femoral heads. From the three cohorts, 75% of the femoral heads showed visual evidence of metal transfer. These femoral heads were analyzed using direct measurement, digital photogrammetry, and white light interferometry. Surface area coverage and curved median surface area were similar among the three cohorts. The most prevalent metal transfer patterns observed were random stripes (n = 21/75), longitudinal stripes (n = 17/75), and random patches (n = 13/75). Metal transfer arc length was shorter in the M-PE cohort. Understanding the morphology of metal transfer may be useful for more realistic recreation of metal transfer in in vitro pin-on-disk and joint simulators studies.


Assuntos
Artroplastia de Quadril/métodos , Cerâmica/efeitos adversos , Ligas de Cromo/efeitos adversos , Prótese de Quadril/efeitos adversos , Cerâmica/uso terapêutico , Ligas de Cromo/uso terapêutico , Cabeça do Fêmur/fisiopatologia , Cabeça do Fêmur/cirurgia , Humanos , Teste de Materiais , Falha de Prótese , Estresse Mecânico
14.
Full dent. sci ; 5(19): 442-447, jul. 2014. ilus, graf
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-726525

RESUMO

A presença de porosidade interna nas estruturas metálicas de próteses parciais removíveis (PPR) é um defeito que pode resultar no fracasso das peças a médio e longo prazo. Os defeitos na peça metálica podem ser identificados de forma direta, por meio da observação visual sem qualquer tipo de aparelhagem, ou de forma indireta, quando os defeitos encontram-se internos à estrutura e, portanto, faz-se necessária a avaliação através de raios-X e/ou fotodensiômetro. Assim, este trabalho propôs uma avaliação desta porosidade por meio de um método simples, conservador e de baixo custo. A radiografia foi realizada com aparelho odontológico de consultório. Avaliaram-se todas as estruturas metálicas que seriam instaladas na clínica de prótese do Curso de Odontologia da EBMSP, durante o segundo semestre do ano de 2010 ao segundo semestre do ano de 2011. Foram analisadas 103 estruturas, sendo 59 superiores e 44 inferiores. Os resultados mostraram 453 bolhas nas estruturas superiores e 30 bolhas nas inferiores. Pôde-se concluir por meio deste estudo que a área do conector maior superior está mais propensa à falha por porosidade interna, quando comparada à área dos conectores inferiores, provavelmente pela sua extensão e dificuldade no escoamento da liga metálica quando fluidificada.


The presence of internal porosity in metal structures of removable partial dentures (RPD) is a defect that medium and long term can result in the failure of parts. Defects on the metal structure can be identified directly (by visual observation without any equipment) or indirectly when the flaws are inside the structure requiring assessment through x-rays or densitometry. Therefore this paper has proposed an evaluation of porosity by means of a simple, conservative and cost-effective method. Radiograph was performed with dental office appliance. All metal structures installed in the prosthetic clinic of the School of Dentistry EBMSP, were submitted to radiographic evaluation of during the second half of 2010 to the second half of 2011. One hundred and three structures were evaluated (44 lower structures and 59 upper strcutures). The results showed 453 bubbles in the upper structures and 30 in the lower. It was concluded that the area of the connector is most susceptible to internal porosity, when compared to the lower area of the connectors, probably due to its size and the difficulty in positioning the sprue and in disposing of the alloy when fluidized


Assuntos
Ligas de Cromo/uso terapêutico , Porosidade , Prótese Parcial Removível , Radiografia Dentária/instrumentação , Estatísticas não Paramétricas
15.
Implant Dent ; 23(2): 212-7, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24637531

RESUMO

PURPOSE: The purpose of this study was to compare the vertical fit of the castable abutment/implant and premachined base metal abutment/implant interface, before and after cyclic loading. MATERIALS AND METHODS: Ten UCLA abutments were distributed in 2 groups: castable and premachined with a cobalt-chromium metal base. The abutments were cast in cobalt-chromium alloy and were screwed onto implants (3.75 × 13 mm, external hexagon) with a 32 N·cm torque. The vertical gap (in micrometers) at the interface abutment/implant was evaluated by linear microscope 2 times: after torque and after cyclic load (1 million cycles, 400 N). RESULTS: The mean values of the vertical gap at the castable abutment/implant and premachined abutment/implant interfaces before and after cyclic load were 5.33 to 6.64 µm and 7.36 to 8.16 µm, respectively. The mean values of the vertical gap were statistically analyzed (ANOVA and t test, P ≤ 0.05). Vertical gap values of the castable abutment/implant interface were not significantly different from those of the premachined abutment/implant interface, before (P = 0.154) and after (P = 0.471) cyclical loading. CONCLUSION: Castable and premachined base metal abutments showed similar gaps at the implant/abutment interface, both after applying torque and after cyclic loading.


Assuntos
Projeto do Implante Dentário-Pivô , Ligas de Cromo/uso terapêutico , Dente Suporte , Técnica de Fundição Odontológica , Implantes Dentários , Análise do Estresse Dentário , Humanos , Torque
16.
Oper Dent ; 39(3): E101-8, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24191870

RESUMO

OBJECTIVES: This study aimed to assess the retention of metal copings luted to uremic teeth with five different luting agents. METHODS: A total of 35 sound natural molars was collected from uremic patients and randomly assigned into five groups (n=7). The teeth were prepared for metal copings using diamond tips and water coolant. Metal copings with a loop on the occlusal surface were fabricated using base metal alloy (Rexillium III). The copings were luted using Fuji I, glass ionomer (GI); Fuji Plus, resin-modified glass ionomer (RMGI); Panavia F 2.0, resin cement; Rely X Unicem, self-adhesive cement (SA); and Adhesor, zinc phosphate cement (ZPh). All specimens were incubated at 37°C for 24 hours, conditioned in artificial saliva for 7 days, and then thermocycled for 5000 cycles (5°C-55°C). The dislodging force was measured using a universal testing machine at a crosshead speed of 2 mm/min. The mode of failure of the loaded adhesive copings was evaluated. Statistical analyses were performed using one-way analysis of variance and Tukey post hoc test. RESULTS: GI and SA cements had the highest and the lowest mean retentive strength, respectively (580.90±17.3, 406.6±12.7). There was no significant difference between ZPh, SA, and resin cements. These cements were inferior to GI and RMGI cements (p<0.05), which showed statistically similar retentive strengths. CONCLUSIONS: The results of this study support the use of glass ionomer and resin-modified glass ionomer cements for luting of metal copings to uremic teeth with retentive preparations.


Assuntos
Ligas de Cromo/uso terapêutico , Coroas , Cimentos Dentários/uso terapêutico , Retenção em Prótese Dentária , Ligas Metalo-Cerâmicas/uso terapêutico , Diálise Renal/efeitos adversos , Uremia/complicações , Falha de Restauração Dentária , Análise do Estresse Dentário , Cimentos de Ionômeros de Vidro/uso terapêutico , Humanos , Uremia/terapia , Cimento de Fosfato de Zinco/uso terapêutico
17.
EuroIntervention ; 8(8): 896-903, 2012 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-23253543

RESUMO

AIMS: The FOCUS registry is a prospective, multicentre, web-based programme designed to collect clinical outcome data from real-world patients receiving the second-generation cobalt-chromium sirolimus-eluting stent (CoCr-SES). METHODS AND RESULTS: From March 2009 to February 2010, a total of 5,084 patients from 83 centres who were eligible to receive CoCr-SES were enrolled in the FOCUS registry. The primary endpoint was 12-month major adverse cardiac events (MACE, defined as the composite of cardiac death, myocardial infarction [MI], and target vessel revascularisation [TVR]). One-year data were available for 5,013 (98.6%) of the 5,084 patients enrolled. The primary endpoint occurred in 174 (3.47%) of 5,013 patients, consisting of 43 (0.86%) cardiac deaths, 132 (2.63%) MI, and 46 (0.92%) TVR. According to the Academic Research Consortium definition, definite and probable stent thrombosis (ST) occurred in 0.52% (26/5,013) of patients, including 19 cases of early ST and 7 of late ST. The 12-month MACE rates were 3.73% and 2.60% for extended-use and standard-use patients, respectively (p=0.065). CONCLUSIONS: The second-generation CoCr-SES was associated with low rates of 12-month MACE and ST in a broad spectrum of patients, thereby confirming the clinical safety and efficacy of this stent in a real-world setting.


Assuntos
Antibióticos Antineoplásicos/uso terapêutico , Doença da Artéria Coronariana/terapia , Stents Farmacológicos/estatística & dados numéricos , Sistema de Registros/estatística & dados numéricos , Sirolimo/uso terapêutico , Idoso , China , Ligas de Cromo/uso terapêutico , Angiografia Coronária , Doença da Artéria Coronariana/mortalidade , Reestenose Coronária/prevenção & controle , Trombose Coronária/prevenção & controle , Falha de Equipamento/estatística & dados numéricos , Feminino , Humanos , Indonésia , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/prevenção & controle , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/estatística & dados numéricos , Estudos Prospectivos , Retratamento/estatística & dados numéricos , Tailândia , Resultado do Tratamento
18.
Trauma (Majadahonda) ; 23(4): 223-227, oct.-dic. 2012. tab, ilus
Artigo em Espanhol | IBECS | ID: ibc-108582

RESUMO

Objetivo: Analizar la degradación de los productos metálicos que constituyen las aleaciones de las prótesis de cadera. Pacientes y método: Se midió, mediante absorción atómica, el titanio, el cromo y el cobalto en la sangre de 58 pacientes con prótesis totales de cadera, compuestas por aleaciones de cromo y cobalto y de titanio, con o sin cementar. Se analizó la evolución de las concentraciones séricas preoperatorias, a los seis y a los 12 meses. Resultados: Encontramos una elevación significativa tras el inicio de la movilización de la articulación, pero sin afectación clínica. Los percentiles 95 de la distribución de concentraciones fueron para el Ti 27 mg/L, Cr 1 mg/L y Co 1,7 mg/L. Conclusión: La elevación de estas concentraciones podría ser indicativa de mal funcionamiento del implante o de desgaste excesivo que podría conducir a toxicidades locales o remotas (AU)


Objective: To analyze the degradation of the metal products contained in hip prosthesis alloys. Patients and method: Atomic absorption measurements were made of the titanium, chromium and cobalt concentrations in the blood of 58 patients with total hip replacement implants made of titanium, chromium and cobalt alloys with or without cementing. The evolution of the serum metal concentrations was assessed based on measurements obtained preoperatively and 6 and 12 months after surgery. Results: A significant increase in serum levels was noted after the start of joint mobilization, though without clinical repercussions. The percentile 95 values of the metal concentration distributions were 27 mg/l for titanium, 1 mg/l in the case of chromium, and 1.7 mg/l for cobalt. Conclusion: The rise in serum metal concentrations could be indicative of poor implant function or excessive wear that in turn could lead to local or disseminated toxicity (AU)


Assuntos
Humanos , Masculino , Feminino , /métodos , /tendências , Metais/análise , Metais/síntese química , Metais/metabolismo , Próteses e Implantes/ultraestrutura , Próteses e Implantes , Titânio/uso terapêutico , Cromo/uso terapêutico , Espectrofotometria Atômica/normas , Espectrofotometria Atômica , Ligas de Cromo/uso terapêutico , Compostos de Cromo/uso terapêutico , Eletroquímica/métodos , Eletroquímica/organização & administração , Análise de Variância
19.
Curr Cardiol Rev ; 8(1): 6-13, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22845811

RESUMO

BACKGROUND: Despite significant improvements in stent platform, currently available bare-metal stents (BMS) are still associated with restenosis. Thin-strut design cobalt-chromium alloys hold the promise of improving results of BMS, especially when implanted with direct technique. We performed an observational study to appraise outcomes of the novel Skylor™ stent, stratifying outcomes according to stenting technique. METHODS AND RESULTS: We included all consecutive patients undergoing coronary stenting with Skylor™ at 2 centers between 2006 and 2009. The primary end-point was the long-term rate of major adverse cardiac events (MACE, i.e. death, myocardial infarction (MI), coronary artery bypass grafting (CABG) or target vessel revascularization (TVR)). As pre-specified analysis, we compared patients undergoing direct stenting versus those stent implantation following predilation. A total of 1020 patients were included (1292 Skylor™ stents), with procedural success obtained in 99%. Comparing patients undergoing direct stenting (66%) versus pre-dilation (34%) at 16±7 months of follow-up, MACE had occurred in, respectively, 8% versus 14% (p=0.001), with death in 1% versus 2= (p=0.380), MI in 1% versus 2% (p=0.032), CABG in 0.2% versus 2% (p=0.012), and TVR in 6% versus 9% [p=0.071]. Even at multivariable analysis with propensity adjustment, direct stenting was associated with significantly fewer MACE [hazard ratio 0.60 [0.38-0.93], p=0.024]. CONCLUSIONS: This observational study suggests the presence of a beneficial synergy between direct coronary stenting technique and use of the novel thin-strut cobalt-chromium Skylor™ stent in real-world patients undergoing PCI.


Assuntos
Reestenose Coronária/etiologia , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/instrumentação , Stents/efeitos adversos , Idoso , Ligas de Cromo/uso terapêutico , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/métodos , Desenho de Prótese , Estudos Retrospectivos , Stents/estatística & dados numéricos , Resultado do Tratamento
20.
Eur Spine J ; 21 Suppl 5: S709-16, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20936310

RESUMO

Pre-clinical wear testing of intervertebral disc prostheses is commonly carried out according to ISO 18192-1. Ten million multiaxial loading cycles are applied at a frequency of 1 Hz. At this frequency, testing takes about 4 months. Testing at higher frequencies would therefore be desirable. ISO 18192-1 also offers testing at 2 Hz; however, it says the impact on the implant material behaviour as well as on the accuracy of the test machine shall be investigated by the user. Since such data are not available so far, the aim of this study was to carry out comparative wear tests at 1 and 2 Hz. Seven Prodisc-L lumbar disc prostheses were tested. After a pre-soak period, the implants were placed in specimen cups filled with calf serum, mounted to a Spine Wear Simulator and loaded according to ISO 18192-1. Testing was carried out at a temperature of 37 ± 2 °C. Four million loading cycles were applied at 1 Hz and eight million at 2 Hz in an alternating sequence. Each time after 12 days of testing the implants were removed to measure the weight and the height of the polyethylene cores. Then, the test serum was exchanged and the implants were remounted to the testing machine. The mean wear rate was 5.6 ± 2.3 mg per million cycles at 1 Hz and 7.7 ± 1.6 mg per million cycles at 2 Hz during the first six million loading cycles (p < 0.05) and 2.0 ± 0.6 and 4.1 ± 0.7 mg per million cycles during the second six million cycles (p < 0.05). Similarly, the mean heightloss was also smaller at 1 Hz than at 2 Hz (p < 0.05) with -0.02 ± 0.02 mm versus -0.04 ± 0.02 mm per million cycles during the first half of testing and -0.01 ± 0.01 versus -0.02 ± 0.01 mm per million cycles during the second half. The accuracy of the test machine was within the limits described by ISO 18192-1 at both frequencies. The results showed that the wear rate was higher at the beginning than at the end of testing. Also, the results indicated that testing at 2 Hz increases the wear rate compared with 1 Hz in case of a polyethylene-on-metal implant design. In the absence of retrieval studies it is difficult to decide which rate results in a more physiological wear pattern. However, a loading frequency of 1 Hz is probably closer to physiology than 2 Hz since the loading amplitudes prescribed by ISO 18192-1 are high. They rather represent movements like tying shoes or standing up from a chair than walking or sitting. The authors therefore suggest testing at 1 Hz.


Assuntos
Ligas de Cromo/uso terapêutico , Análise de Falha de Equipamento/métodos , Polietileno/uso terapêutico , Substituição Total de Disco/métodos , Suporte de Carga/fisiologia , Análise de Falha de Equipamento/instrumentação , Humanos , Disco Intervertebral/fisiologia , Disco Intervertebral/cirurgia , Vértebras Lombares/fisiologia , Vértebras Lombares/cirurgia , Movimento/fisiologia , Postura/fisiologia , Desenho de Prótese/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...